Thimble sizes should be selected carefully to fit extractors correctly. The different sizes represent the established practice of showing the internal diameter and overall length of the thimble in millimetres. Therefore, an extra allowance for wall thickness should be made when calculating external diameters. The thimble should pass through the narrower end of the upper extractor socket, allowing 1-2 mm clearance, and be 5-10 mm above the level of the top of the siphon tube.




Thimble  Media Selection:
  
Cellulose
  
Thimbles made of high grade cotton cellulose. Smooth interior surface. Absolutely seamless. Fit most Soxhlet extraction devices
  
Fat determination of meat and diary products
Determination of PCB in fish products

Determination of free fats in food products

Determination of pesticide residues in food products

Extraction of plasticizers from PVC

Determination of organic compounds in washing agents

Extraction of additives from livestock feed

Extraction of dioxins

Solid particle such as dust collection in air flows

Evaluation of liquid content in concrete slurry
      
Glass Microfiber
  
High purity glass microfiber thimbles used for high temperature filtration, up to 550°C (1022°F), or when using solvents incompatible with cellulose thimbles.

Gravimetric methods for hot environments

Gravimetric methods for acidic gasses

Extraction methods common to biochemical analysis
  



Thimble Size Selection:

Thimble sizes should be selected carefully to fit extractors correctly. The different sizes represent the established practice of showing the internal diameter and overall length of the thimble in millimetres. Therefore, an extra allowance for wall thickness should be made when calculating external diameters. The thimble should pass through the narrower end of the upper extractor socket, allowing 1-2 mm clearance, and be 5-10 mm above the level of the top of the siphon tube.



  
Due to the large number of extraction thimble parts,
we kindly ask that you contact us directly to receive
part numbers, pricing, volume discounts and availability
if you can't find the thimbles or information you  require listed below.

Extraction Thimbles can be found here

Other Lab Filters can be found here

Laoratory Water Products can be found here


Shopping Cart
Total items : 0
Cart Total : $0.00

Free Shipping Continental USA


Got questions?
I am here to help



Just Ask Henry
.
Click Here!

Canadian Clients
Click Here

For
Wyvern Scientific

Lab Water Clients
Click Here

Save up to 50%

Residential & Commercial Water Clients
Click Here

Save up to 50%

Related Categories
Mixed Cellulose - Flat Stock Filter Paper
Glass Microfiber Filtration - Flat Stock Filter Paper
Syringe Filters
Extraction Thimbles
Capsule Filters

Contact Us
Live Hours
7:00a-4:00p p.s.t.
Monday-Friday

Toll Free
800-460-9011

local/International
818-786-0600

Fax
818-786-2347

E-MAIL US



Tags : About | Extraction | Thimbles | - | Size | Membrane | Selection | Thimble | sizes | be | selected | carefully | fit | extractors | correctly | The | different | sizes | represent | the | established | practic
About Extraction Thimbles - Size and Membrane Selection


                                                                    Terms and conditions                Privacy Policy                                                                       

 

All freight charges quoted on this web site are for continental USA only. Freight is calculated based on a starting point of Van Nuys, California. 91406 shipping from a business location to a business location. If we ship your order out of warehouses located in other locations or if you are in a rural or residential location, your freight charges may differ significantly. You will be notified if the freight charges on your order differ. 

 

Images are representative of the product and not necessarily the actual image of the product. 

 

*To the extent that APS WATER uses trademarks, servicemarks, tradenames, or other identifying information of other companies, APS WATER is making use of those Trademarks for identification, or is making use by permission. The owner of the trademarks has not consented to further use or copying of the trademarks and APS WATER can not license such trademarks. Millipore , Q-Pak , Super-Q , Super-C , Milli-Q , ROGARD , Milli-RO , ROPAK , AFSPAK , Polygard, Gradient, Synthesis, AFS, SDS, Acadenic, Biocel, Element, progard, ggard, quantum, Millipak  and any tradenames prefixed by the words Millipore or Millipore's are trademarks of Millipore Corporation. Barnstead, Nanopure ,  E-pure , B-pure , Nanopure Diamond,Infinity , Easypure , ROPURE , Bantam and Mega-pure  are trademarks of Barnstead/Thermolyne. Labconco and Waterpro are trademarks of Labconco inc. Continental, IWT, US Filter, Modulab and Culligan and other water related trademarks are trademarks of their respective owners. 

This is not necessarily a full list of the trademark notifications we must make, If you see one we inadvertently left off, 

please contact 800-460-9011 to have it added.

 

© 2001-2008 APS Water Services Inc. All Rights Reserved.   
APS
ULTRA brand water purification products are designed to be replacement filters and membranes for Millipore , Barnstead , and US Filter water purification systems.

934-AH® is a registered trademark of Whatman Inc. and used under license